94
Excavator Supplement for 3066 Engine
Disassembly and Assembly Section
WARNING
Personal injury can result from contact with refrig-
erant.
Contact with refrigerant can cause frost bite. Keep
face and hands away to help prevent injury.
Protective goggles must always be worn when re-
frigerant lines are opened, even if the gauges in-
dicate the system is empty of refrigerant.
Always use precaution when a fitting is removed.
Slowly loosen the fitting. If the system is still under
pressure, release it slowly in a well ventilated area.
Personal injury or death can result from inhaling
refrigerant through a lit cigarette.
Inhaling air conditioner refrigerant gas through a
lit cigarette or other smoking method or inhaling
fumes released from a flame contacting air con-
ditioner refrigerant gas, can cause bodily harm or
death.
Do not smoke when servicing air conditioners or
wherever refrigerant gas may be present.
Use a certified recovery and recycling cart to prop-
erly remove the refrigerant from the air condition-
ing system.
Refrigerant Condenser
Remove and Install
SMCSCode: 1805-010
S/N: ANB1-Up
S/N: BDB1-Up
S/N: BGB1-Up
S/N: AMC1-Up
S/N: BBC1-Up
S/N: BDC1-Up
S/N: CCD1-Up
S/N: BEF1-Up
S/N: BKK1-Up
S/N: CLM1-Up
S/N: BER1-Up
S/N: BPR1-Up
S/N: BRX1-Up
S/N: CLZ1-Up
5. Evacuate the air conditioning system.
Reference: Refer to Testing and Adjusting,
"Refrigerant System - Evacuate" for the correct
procedure.
6. Charge the air conditioning system. The correct
charge is 1.1 kg (2.4 lb).
Reference: Refer to Testing and Adjusting,
"Refrigerant System - Charge" for the correct
procedure.
7. Check the air conditioning system for leaks.
Note: Use a 4C-2964 Refrigerant Leak Detector to
check the system.
End By:
a. Install the V-belt on the refrigerant compressor.
Refer to Disassembly and Assembly, "V-Belts -
Remove and Install" in this manual.
b. Install the hood on the refrigerant compressor.
Refer to Disassembly and Assembly, "Hood -
Remove and Install" in this manual.