Page 174
PTO Engine RPM Set Speed Input A /
OEM
/
Description:
The PTO Engine RPM Set Speed Input A switch is used
to control the engine speed during PTO operation.
Specifi cally, this parameter is set to set engine speed
to the engine speed specifi ed by the PTO Engine RPM
Set Speed A parameter. For the PTO Engine RPM Set
Speed Input A to work properly, the PTO Confi guration
parameter must be programmed to Cab Switches,
Remote Switches, or Remote Throttle, and the PTO
Engine RPM Set Speed A parameter must be set to a
valid engine speed.
Available:
All electronically programmable on-highway engines
covered in this handbook
Range:
Engine Range
Cat
Default
3126E, C7, C9
(PM MAR03 and before)
J1/P1:46 None
3126E, C7, C9
(PM MAR04 and after)
J1/P1:46, J1939 Cab
Controller, J1939 Body
Controller, J1939 Instru-
ment Cluster
None
C-10, C-12, C-15, C-16
(PM OCT01 and before)
J1/P1:6, J1/P1:46, J1/P1:58,
J1/P1:60
None
C-10, C-12, C-15, C-16
(PM JAN02 and after)
C11, C13, C15
J1/P1:6, J1/P1:46,
J1/P1:58, J1/P1:60,
J1939 Body Controller,
J1939 Cab Controller,
J1939 Instrument Cluster
None
EPA’07 and newer C7,
C9, C13, C15
J1/P1:6, 7, 22, 23, 35, 40, 44,
45, 46, 47, 56, 58, 59, 60,
Or
J1939 Body Controller
J1939 Cab Controller
J1939 Instrument Cluster
J1939 Cab Display
None
Advantages:
This parameter allows the operator to adjust the engine
speed to the speed specifi ed by the PTO Engine RPM Set
Speed A parameter.
Disadvantages:
None
Input Selection